laboratory automatic 550C differential scanning calorimetry oit oxidative induction time determination equipment tester

DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature (Tg), melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
Standards:
ISO/TR10837:1991,ASTM D3895-1998,ASTM E 967,ASTM E 968,ASTM E 793,ASTM D 3895, ASTM D 3417,ASTM D 3418, ISO 11357-6
Main Features:
1. The industrial-grade 7-inch touch screen displaysrichinformation.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy.The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communicationinterface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gasinput is added.
5. The softwareis simple andeasy to operate.

Specification

Temperature range
RT~ 550 ℃
Heating rate
0.1~80℃/min
Temperature resolution
0.001℃
Temperature fluctuations
±0.001℃
Temperature repeatability
±0.1℃
Constant temperature time
Program setting ≤24h
DSC range
0~±600mW
DSC noise
0.01μW
DSC resolution
0.01μW
DSC accuracy
0.01mW
Atmosphere control gas
Nitrogen, Oxygen (instrument switch automatically)
Gas flow rate
0-300mL/min
Gas pressure
0.2MPa
Control Mode
Rising temperature, constant temperature(full automatic)
Curve scanning
Rising scan
Gas flow control
Built-in digital flow meter & Software control, automatic
Display
24 bit 7 inches LCD touch screen display
Data interface
standard USB connector
Parameter standard
With standard material, with calibration function, the user may correct temperature and heat enthalpy
Software
operating software
Thermocouples
Total 3 sets of thermocouples for:

1). Test sample temperature

2). test furnace temperature,

3). Test internal ambient temperature
Cooling device
Air cool
Power
AC220V/50Hz

Product details

Additional information

Use

Temperature resolution:0.001 ℃

,

DSC range: 0~±600mW

Customer Reviews

Reviews

There are no reviews yet.

Be the first to review “Laboratory Automatic 550C Differential Scanning Calorimetry Oit Oxidative Induction Time Determination Equipment Tester”